Feb 17, 2025

Recently, a comment on our social media post attracted my attention. It was a question of European buyers of solar energy storage systems who accidentally purchased a three-phase 380V hybrid inverter instead of the single-phase 230V model they needed, causing their system to fail. We have proposed our solution, and the inverter now is running smoothly.

The Fix:

We installed an AC distribution box between the inverter and the load, allowing the three-phase inverter to power multiple single-phase loads. Here’s how it works:

Connect the three-phase inverter to the circuit breaker (A) via the UPS port.

Link the circuit breaker (A) to three circuit breakers (B) using four busbars:                     

    L1 → L1, L2 → L2, L3 → L3, the neutral wires from the breakers (B) are combined and connected to the neutral wire of the breaker (A).

Connect three breakers (B) to the home loads separately.

Key Notes:

1. Each single-phase load must not exceed 6kW, and the total load must stay within the inverter’s capacity.

2. This solution works for systems under 20kW.

3. A three-phase inverter can power single-phase loads, but a single-phase inverter cannot support three-phase loads.

 

Facing a similar issue or technical headaches? Don’t worry—contact us for expert advice and solutions!

 

Contact now:
Business Consulting: Karen Wang

Mobile/Whatsapp/Wechat:  +86 189 0569 0996  /  Email:  info@ue-pv.com  

 

 Technical Consulting: Simon Peng 

Mobile/Whatsapp/Wechat:  +86 186 1698 9760  /  Email:  simon@ue-pv.com

laat een bericht achter

laat een bericht achter
Als je geïnteresseerd bent en meer details wilt weten, laat dan hier een bericht achter, we zullen je zo snel mogelijk antwoorden.
Submit

Home

products

whatsApp

contact